Zhenglan Cable Technology Co., Ltd

Zhenglan Cable Technology Co.,Ltd Make Cable with Heart!

Manufacturer from China
Verified Supplier
6 Years
Home / Products / Bare Aluminum Conductor /

ACSR Skunk Bare Aluminum Conductor AL-12/2.59mm St-7/2.59mm EN50182

China ACSR Skunk Bare Aluminum Conductor AL-12/2.59mm St-7/2.59mm EN50182 wholesale
  • China ACSR Skunk Bare Aluminum Conductor AL-12/2.59mm St-7/2.59mm EN50182 wholesale
  • China ACSR Skunk Bare Aluminum Conductor AL-12/2.59mm St-7/2.59mm EN50182 wholesale

ACSR Skunk Bare Aluminum Conductor AL-12/2.59mm St-7/2.59mm EN50182

Ask Latest Price
Brand Name :Zhenglan Cable
Model Number :bare ACSR conductor Skunk (AL-12/2.59mm, St-7/2.59mm) EN50182
Certification :ISO 9001:2020, ISO 14001:2020
Place of Origin :Henan, China
MOQ :300 meters
Payment Terms :L/C, T/T,
Delivery Time :15 days
Packaging Details :Wooden drum, wood and steel drum,as customer's request
Material :AL/Steel
Standard :IEC61089, En50182
Core :Normal or Customized
characted :Bare Conductor
Application :Overhead transmission use
Total Area :18.7~1211
Contact Now

Add to Cart

Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
View Product Description

bare ACSR conductor Skunk (AL-12/2.59mm, St-7/2.59mm) EN50182

ACSR Conductor APPLICATION

ACSR conductors are widely used for electrical power transmission over long distances, since they are ideal for long overhead lines spans. They are also used as a messenger for supporting overhead electrical cables.

ACSR Conductor STANDARD

Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards.

Note: The values of current rating mentioned in above Table are based on wind velocity of 0.6 metre/second, solar heat radiation of 1200 watt/metre2, ambient temperature of 50° C & conductor temperature of 80°C.

ACSR Conductor CONSTRUCTION

ACSR conductors are formed by several wires of aluminium and galvanized steel, stranded in concentric layers. The wire or wires which form the core, are made of galvanized steel and the external layer or layers, are of aluminium. Galvanized steel core consist normally of 1, 7 or 19 wires. The diameters of steel and aluminium wires can be the same, or different.

By varying the relative proportions of aluminium and steel, the required characteristics for any particular application can be reached. A higher U. T. S. Can be obtained, by increasing steel content, and a higher current carrying capacity by increasing aluminium content.

ACSR Conductor ELECTRICAL PROPERTIES

density@20ºC Aluminium: 2.703 kg/dm
Galvanised Steel: 7.80 kg/dm
Temperature Coefficient@20°C Aluminium: 0.00403 (°C)
resistivity@20°C Aluminium: Should not exceed 0.028264

linear Expansivity

Aluminium: 23 x10 (°C)
Galvanised Steel: 11.5 x10 (1/°C)

SERVICE CONDITIONS

Ambient Temperature -5°C - 50°C
Wind Pressure 80 – 130kg/m
Seismic Acceleration 0.12 - 0.05g
Isokeraunic level 10 – 18
relative Humidity 5 – 100%

ACSR Conductor TECHNICAL DATA

Numbers of Wires Modules of Elasticity Coeficient of linear Expansion
AL STEEL Kg/mm2 Lb/in2 1/Cº 1/Fº
6 1 81 11.5 x106 19.1 x10-6 10.6 x10-6
6 7 77 11.0 x106 19.8 x10-6 11.0 x10-6
12 7 107 15.2 x106 15.3 x10-6 8.5 x10-6
18 1 67 9.5 x106 21.2 x10-6 11.8 x10-6
24 7 74 10.5 x106 19.6 x10-6 10.9 x10-6
26 7 77 10.9 x106 18.9 x10-6 10.5 x10-6
28 7 79 11.2 x106 18.4 x10-6 10.2 x10-6
30 7 82 11.6 x106 17.8 x10-6 9.9 x10-6
30 19 80 11.4 x106 18.0 x10-6 10.0 x10-6
32 19 82 11.7 x106 17.5 x10-6 9.7 x10-6
54 7 70 9.9 x106 19.3 x10-6 10.7 x10-6
54 19 68 9.7 x106 19.4 x10-6 10.8 x10-6

bare ACSR conductor Skunk (AL-12/2.59mm, St-7/2.59mm) EN50182 technical data sheet

BRITISH STANDARD EN 50182: 2001
Code Old Code Area No. of Wires Wire Diameter Diameter Mass per Unit Rated Strength DC Resistance
AL Steel Total AL Steel AL Steel Core Cond. Length
mm2 2 mm 2 mm mm mm mm mm kg/km kN Q/km
11-AL1/2-ST1A MOLE 10.6 1.77 12.4 6 1 1.5 1.5 1.5 4.5 42.8 4.14 2.7027
21-AL1/3-ST1A SQUIRREL 21 3.5 24.5 6 1 2.11 2.11 2.11 6.33 84.7 7.87 1.3659
26-AL1/4-ST1A GOPHER 26.2 4.37 30.6 6 1 2.36 2.36 2.36 7.08 106 9.58 1.0919
32-AL1 巧-ST1A WEASEL 31.6 5.27 36.9 6 1 2.59 2.59 2.59 7.77 127.6 11.38 0.9065
37-AL1/6-ST1A FOX 36.7 6.11 42.8 6 1 2.79 2.79 2.79 8.37 148.1 13.21 0.7812
42-AL1/7-ST1A FERRET 42.4 7.07 49.5 6 1 3 3 3 9 171.2 15.27 0.6757
53-AL1/9-ST1A RABBIT 52.9 8.81 61.7 6 1 3.35 3.35 3.35 10.1 213.5 18.42 0.5419
63-AL1/11-ST1A MINK 63.1 10.5 73.6 6 1 3.66 3.66 3.66 11 254.9 21.67 0.454
63-AL1/37-ST1A SKUNK 63.2 36.9 100.1 12 7 2.59 2.59 7.77 13 463 52.79 0.4568
75-AL1/13-ST1A BEAVER 75 12.5 87.5 6 1 3.99 3.99 3.99 12 302.9 25.76 0.382
73-AL1/43-ST1A HORSE 73.4 42.8 116.2 12 7 2.79 2.79 8.37 14 537.3 61.26 0.3936
79-AL1/13-ST1A RACOON 78.8 13.1 92 6 1 4.09 4.09 4.09 12.3 318.3 27.06 0.3635
84-AL1/14-ST1A OTTER 83.9 14 97.9 6 1 4.22 4.22 4.22 12.7 338.8 28.81 0.3415
95-AL1/16-ST1A CAT 95.4 15.9 111.3 6 1 4.5 4.5 4.5 13.5 385.3 32.76 0.3003
105-AL1/17-ST1A HARE 105 17.5 122.5 6 1 4.72 4.72 4.72 14.2 423.8 36.04 0.273
105-AL1/14-ST1A DOG 105 13.6 118.5 6 7 1.57 1.57 4.71 14.2 394 32.65 0.2733
132-AL1/20-ST1A COYOTE 131.7 20.1 151.8 26 7 1.91 1.91 5.73 15.9 520.7 45.86 0.2192
132-AL1/7-ST1A COUGAR 131.5 7.31 138.8 18 1 3.05 3.05 3.05 15.3 418.8 29.74 0.2188
131-AL1/31-ST1A TIGER 131.2 30.6 161.9 30 7 2.36 2.36 7.08 16.5 602.2 57.87 0.2202
158-AL1/37-ST1A WOLF 158.1 36.9 194.9 30 7 2.59 2.59 7.77 18.1 725.3 68.91 0.1829
159-AL1/9-ST1A DINGO 158.7 8.81 167.5 18 1 3.35 3.35 3.35 16.8 505.2 35.87 0.1814
183-AL1/43-ST1A LYNX 183.4 42.8 226.2 30 7 2.79 2.79 8.37 19.5 841.6 79.97 0.1576
184-AL1/10-ST1A CARACAL 184.2 10.2 194.5 18 1 3.61 3.61 3.61 18.1 586.7 40.74 0.1562
212-AL1/49-ST1A PANTHER 212.1 49.5 261.5 30 7 3 3 9 21 973.1 92.46 0.1363
211-AL1/12-ST1A JAGUAR 210.6 11.7 222.3 18 1 3.86 3.86 3.86 19.3 670.8 46.57 0.1366
238-AL1/56-ST1A LION 238.3 55.6 293.9 30 7 3.18 3.18 9.54 22.3 1093.4 100.47 0.1213
264-AL1/62-ST1A BEAR 264.4 61.7 326.1 30 7 3.35 3.35 10.1 23.5 1213.4 111.5 0.1093
324-AL1/76-STA GOAT 324.3 75.7 400 30 7 3.71 3.71 11.1 26 1488.2 135.13 0.0891
375-AL1/88-ST1A SHEEP 375.1 87.5 462.6 30 7 3.99 3.99 12 27.9 1721.3 156.3 0.0771
374-AL1/48-ST1A ANTELOPE 374.1 48.5 422.6 54 7 2.97 2.97 8.91 26.7 1413.8 118.88 0.0773
382-AL1/49-ST1A BISON 381.7 49.5 431.2 54 7 3 3 9 27 1442.5 121.3 0.0758

CONSTRUCTION PARAMETERS

• IEC 60189

Code Nominal Area Stranding Overall Diameter Weight Breaking Load Electrical Resistance @20° Current Rating*
AL STEEL TOTAL AL STEEL
mm2 mm2 mm2 No.xmm No.xmm mm Kg/Km KN Ω/Km A
16 16 2.67 18.7 6/1.84 1/1.84 5.52 64.6 6.08 1.7934 85
25 25 4.17 29.2 6/2.30 1/2.30 6.9 100.9 9.13 1.1478 112
40 40 6.67 46.7 6/2.91 1/2.91 8.73 161.5 14.4 0.7174 150
63 63 10.5 73.5 6/3.66 1/3.66 10.98 254.4 21.63 0.4555 198
100 100 16.7 117 6/4.61 1/4.61 13.83 403.8 34.33 0.2869 263
125 125 6.94 132 18/2.97 1/2.97 14.85 397.9 29.17 0.2304 299
125 125 20.4 145 26/2.47 7/1.92 15.64 503.9 45.69 0.231 302
160 160 8.89 169 18/3.36 1/3.36 16.8 509.3 36.18 0.18 347
160 160 26.1 186 26/2.80 7/2.18 17.74 644.9 57.69 0.1805 351
200 200 11.1 211 18/3.76 1/3.76 18.8 636.7 44.22 0.144 398
200 200 32.6 233 26/3.13 7/2.43 19.81 806.2 70.13 0.1444 402
250 250 24.6 275 22/3.80 7/2.11 21.53 880.6 68.72 0.1154 458
250 250 40.7 291 26/3.50 7/2.72 22.16 1007.7 87.67 0.1155 461
315 315 21.8 337 45/2.99 7/1.99 23.91 1039.6 79.03 0.0917 526
315 315 51.3 366 26/3.93 7/3.05 24.87 1269.7 106.83 0.0917 530
400 400 27.7 428 45/3.36 7/2.24 26.88 1320.1 98.36 0.0722 607
400 400 51.9 452 54/3.07 7/3.07 27.63 1510.3 123.04 0.0723 610
450 450 31.1 481 45/3.57 7/2.38 28.56 1485.2 107.47 0.0642 651
450 450 58.3 508 54/3.26 7/3.26 29.34 1699.1 138.42 0.0643 655
500 500 34.6 535 45/3.76 7/2.51 30.09 1650.2 119.41 0.0578 693
500 500 64.8 565 54/3.43 7/3.43 30.87 1887.9 153.8 0.0578 697
560 560 38.7 599 45/3.98 7/2.65 31.83 1848.2 133.74 0.0516 741
560* 560 70.9 631 54/3.63 19/2.18 32.68 2103.4 172.59 0.0516 745
630 630 43.6 674 45/4.22 7/2.81 33.75 2079.2 150.45 0.0459 794
630* 630 79.8 710 54/3.85 19/2.31 34.65 2366.3 191.77 0.0459 798
710 710 49.1 759 45/4.48 7/2.99 35.85 2343.2 169.56 0.0407 851
710* 710 89.9 800 54/4.09 19/2.45 36.79 2666.8 216.12 0.0407 856
800* 800 34.6 835 72/3.76 7/2.51 37.61 2480.2 167.41 0.0361 910
800* 800 66.7 867 84/3.48 7/3.48 38.28 2732.7 205.33 0.0362 912
800* 800 101 901 54/4.34 19/2.61 39.09 3004.9 243.52 0.0362 916
900* 900 38.9 939 72/3.99 7/2.66 39.9 2790.2 188.33 0.0321 972
900* 900 75 975 84/3.69 7/3.69 40.59 3074.2 226.5 0.0322 974
1000* 1000 43.2 1043 72/4.21 7/2.80 42.08 3100.3 209.26 0.0289 1031
1120* 1120 47.3 1167 72/4.45 19/1.78 44.5 3464.9 234.53 0.0258 1096
1120* 1120 91.2 1211 84/4.12 19/2.47 45.31 3811.5 283.17 0.0258 1100
1250* 1250 102 1352 84/4.35 19/2.61 47.85 4253.9 316.04 0.0232 1165
1250* 1250 52.8 1303 72/4.70 19/1.88 47 3867.1 261.75 0.0231 1163
1120* 1120 91.2 1211 84/4.12 19/2.47 45.31 3811.5 283.17 0.0258 1100

bare ACSR conductor Skunk (AL-12/2.59mm, St-7/2.59mm) EN50182 images

ACSR Skunk Bare Aluminum Conductor AL-12/2.59mm St-7/2.59mm EN50182

ACSR Skunk Bare Aluminum Conductor AL-12/2.59mm St-7/2.59mm EN50182

Why you choose us?

  • OEM/ODM services provided;
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;
  • Professional pre-sales and after-sales services provided.
China ACSR Skunk Bare Aluminum Conductor AL-12/2.59mm St-7/2.59mm EN50182 for sale

ACSR Skunk Bare Aluminum Conductor AL-12/2.59mm St-7/2.59mm EN50182

Inquiry Cart 0