Zhenglan Cable Technology Co., Ltd

Zhenglan Cable Technology Co., Ltd Make Cable with Heart!

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Twin And Earth Cable /

High Temperature RV Twin And Earth Cable ISO 9001:2015 Certificated/(450/750) PVC insulated cables

Contact Now
Zhenglan Cable Technology Co., Ltd
Visit Website
City:zhengzhou
Province/State:henan
Country/Region:china
Contact Person:MissLinda Yang
Contact Now

High Temperature RV Twin And Earth Cable ISO 9001:2015 Certificated/(450/750) PVC insulated cables

Ask Latest Price
Video Channel
Brand Name :Zhenglan cable
Model Number :RV Cable(450/750) PVC insulated cables
Certification :3C,ISO 9001:2015,ISO 14001:2005
Place of Origin :China
MOQ :100 meters
Payment Terms :L/C, T/T,
Delivery Time :5~10 days
Packaging Details :Rolls
Material :99.99% oxygen free copper
Type :PVC insulated
Application :for home use
Voltage :450/750V
Nominal section area :1.5~70mm²
more
Contact Now

Add to Cart

Find Similar Videos
PVC Insulated Twin And Earth Cable /BVV Cable 300/500V For Home / Building/Core Number: 2 Core, 3 Core, 4 Core Or 5 Core 01:00
PVC Insulated Twin And Earth Cable /BVV Cable 300/500V For Home / Building/Core Number: 2 Core, 3 Core, 4 Core Or 5 Core
AAAC Overhead Bare Conductor Wire (AAC,AAAC,ACSR) /AWG Cable/100% test Cable/Aluminum, aluminum alloy 00:09
AAAC Overhead Bare Conductor Wire (AAC,AAAC,ACSR) /AWG Cable/100% test Cable/Aluminum, aluminum alloy
4 Cores /4+1 Core Fire Resistant Cable/ Mica Tape XLPE Insulated Sheathed Fire Proof Cable( Unarmoured ) 00:32
4 Cores /4+1 Core Fire Resistant Cable/ Mica Tape XLPE Insulated Sheathed Fire Proof Cable( Unarmoured )
1kv Low Voltage Power Cable 4*35mm2 XLPE Insulated SWA Armored Power Cable IEC60502-1 00:19
1kv Low Voltage Power Cable 4*35mm2 XLPE Insulated SWA Armored Power Cable IEC60502-1
Overhead Bare Conductor Wire/Cable (Area AL:40mm2 Steel:6.67mm2 Total:46.7mm2) (AAC,AAAC,ACSR) 00:05
Overhead Bare Conductor Wire/Cable (Area AL:40mm2 Steel:6.67mm2 Total:46.7mm2) (AAC,AAAC,ACSR)
Oxygen Free Copper Fire Resistant Cables/ BVV Cable For Building Electrical Wire/Rated Voltage: 450/750 V 05:58
Oxygen Free Copper Fire Resistant Cables/ BVV Cable For Building Electrical Wire/Rated Voltage: 450/750 V
Armoured Steel Tape PVC Insulated Copper Cable 8.7 / 15 KV For Indoor And Outdoor(CU/PVC/XLPE/STA/NYBY/NYRGBY) 00:16
Armoured Steel Tape PVC Insulated Copper Cable 8.7 / 15 KV For Indoor And Outdoor(CU/PVC/XLPE/STA/NYBY/NYRGBY)
3*2.5~3*500mm2 0.6/1KV Three Cores LV Power Cable XLPE Armored Cable 00:12
3*2.5~3*500mm2 0.6/1KV Three Cores LV Power Cable XLPE Armored Cable
Nominal Section:3*25~3*400mm² 3 Cores 0.6/1kV CU/AL LV Cable, XLPE Insulated Armoured Power Cable(AL/CU/N2XB2Y) 01:02
Nominal Section:3*25~3*400mm² 3 Cores 0.6/1kV CU/AL LV Cable, XLPE Insulated Armoured Power Cable(AL/CU/N2XB2Y)
View Product Description

High Temperature RV Twin And Earth Cable ISO 9001:2015 ISO 14001:2005 Certificated/(450/750) PVC insulated cables

Twin And Earth Cable Application:

RV cable is widely used in industrial distribution field. It is especially suitable for flexible installation places with stricter requirements, such as electronic control cabinets, distribution boxes and various low-voltage electrical equipment. It can be used for transmission of power, electrical control signals and switching signals. RV wire and cable are designed with soft structure. The bending radius of conductor is small, and it is suitable for wet and oily installation places.

Twin And Earth Cable Construction characteristics

Conductor: flexible conductor class 5 (China GB/T 3956 class 5 or

IEC60228 class 5)

Insulation: PVC

Rated voltage and standard:

300/500V 60227 IEC06 or GB/T5023.3-2008

450/750V 60227 IEC02 or GB/T5023.3-2008

Minimum service temperature: - 30 C

Maximum service temperature available +70 °C, +90 °C, +105 °C

Packaging: 100m/roll or as request

Remarks: Flame retardant, fire resistance (adopt mica tape), low smoking and Halogen free, or other property are available.

ZR cable (flame retardant cable) is the kind of cable with PVC insulation built mixed with fire prevention additive to make it have the capability of preventing or retarding flame spread during combustion.

There are 3 grades of fire prevention available which are

Grade A It is the highest level of flame retardancy. That is, the insulation material, filling rope, fastening (inner cushion) belt/layer and sheath material used in cables are all flame retardant materials.

Grade B Except the insulation material, all other materials are flame retardant.

Grade C Only the sheath material is flame retardant

NH cable (fire resistant cable) is the kind of cable built with a layer of mica tape. Even if the plastic skin is burnt out, refractory layer will help not cause short circuit. When wiring, cut off the refractory layer at the wire head.

LSZH,LSOH,LS0H,LSFH or OHLS cable(Low smoke zero halogen cable)is cable with insulation or outer sheath built using low smoke zero halogen free material to help reduce toxic and corrosive gases produced during combustion.

Termite-proof cable is the cable built with insulation or outer sheath mixed with a kind of materials to prevent termite biting the cable.

Twin And Earth Cable Data sheet

300/500V

Nominal section area(mm²) No ./Dia.
of
Strand
(mm)
Nom.
Thickness
of insulation
(mm)
Average
OD Max.
(mm)
Max. DC conductor
resistance at 20℃
(Ω/km)
Min. Insulating
resistance
at 70℃
(MΩ·km)
1*0.5 16/0.2 0.6 2.6 9.1 0.013
1*0.75 24/0.2 0.6 2.8 12.2 0.011
1*1.0 32/0.2 0.6 3.0 15.1 0.010

RV-90℃

Nominal section area(mm²) Core no./dia(mm)

Max diameter

(mm)

Insulation thickness

(mm)

Reference weight

(kg/km)

90℃Minimum insulation electric resistance(mΩ/km)
1*0.5 16/0.2 2.5 0.6 10.2 0.013
1*0.75 24/0.2 2.7 0.6 13.5 0.012
1*1.0 32/0.2 2.8 0.6 16.4 0.010
1*1.5 30/0.25 3.4 0.7 21.4 0.009
1*2.5 49/0.25 4.1 0.8 34.5 0.009

450/750V

Nominal section area(mm²) No ./Dia.
of
Strand
mm
Nom.
Thickness
of insulation
mm
Average
OD (Max.)
mm
Max. DC conductor
resistance at 20℃
Ω/km
Min. Insulating
resistance
at 70℃
MΩ·km
1*1.5 30/0.25 0.7 3.5 13.3 0.010
1*2.5 50/0.25 0.8 4.2 7.98 0.009
1*4 77/0.26 0.8 4.8 4.95 0.007
1*6 78/0.31 0.8 6.3 3.30 0.006
1*10 84/0.39 1.0 7.6 1.91 0.0056
1*16 133/0.39 1.0 8.8 1.21 0.0046
1*25 189/0.41 1.2 11.0 0.78 0.0044
1*35 259/0.41 1.2 12.5 0.554 0.0038
1*50 361/0.41 1.4 14.5 0.386 0.0037
1*70 337/0.51 1.4 17.0 0.272 0.0032

Inquiry Cart 0
You May Like
Twin Cable 2 Core With Earth 2x1.5mm2+1mm2, 2x2.5mm2+1.5mm2 CU/PVC/PVC 300/500V
Twin Cable 2 Core With Earth 2x1.5mm2+1mm2, 2x2.5mm2+1.5mm2 CU/PVC/PVC 300/500V
Flexible Wire Copper Conductor PVC Insulation For Building And House
Flexible Wire Copper Conductor PVC Insulation For Building And House
IEC 60227 Standard Single Wire (450/750) Copper Conductor With PVC Insulated Home Or Building
IEC 60227 Standard Single Wire (450/750) Copper Conductor With PVC Insulated Home Or Building
300/500v BV Electrical Wire For Home For Building Use Accroding To IEC 60227/3C,ISO 9001:2015
300/500v BV Electrical Wire For Home For Building Use Accroding To IEC 60227/3C,ISO 9001:2015
High Performance Cable / Moistureproof BV Cable For Laying Tubes Area: 1*1.5~1*400mm²
High Performance Cable / Moistureproof BV Cable For Laying Tubes Area: 1*1.5~1*400mm²
Tinned Copper Flexible Electric Wires 2 3 4 5 6 Core 1.5mm 4mm 6mm 10mm 16mm 50mm 70mm
Tinned Copper Flexible Electric Wires 2 3 4 5 6 Core 1.5mm 4mm 6mm 10mm 16mm 50mm 70mm
Building And House Wire For IEC 60227 /GB/T5023.3-2008 Standard/BV Cable(450/750) PVC Insulated Use For Home Or Building
Building And House Wire For IEC 60227 /GB/T5023.3-2008 Standard/BV Cable(450/750) PVC Insulated Use For Home Or Building
High Temperature RV Twin And Earth Cable ISO 9001:2015 Certificated/(450/750) PVC insulated cables
High Temperature RV Twin And Earth Cable ISO 9001:2015 Certificated/(450/750) PVC insulated cables
RVV Fire Resistant Twin And Earth Cable , House Wire Cable have PVC insulated  (300/500V)
RVV Fire Resistant Twin And Earth Cable , House Wire Cable have PVC insulated (300/500V)
PVC Insulated Twin And Earth Cable /BVV Cable 300/500V For Home / Building/Core Number: 2 Core, 3 Core, 4 Core Or 5 Core
PVC Insulated Twin And Earth Cable /BVV Cable 300/500V For Home / Building/Core Number: 2 Core, 3 Core, 4 Core Or 5 Core
300/500V Oxygen Free Copper Wire/PVC Insulated And The Core From 2~3 /Standard: IEC227-4 Or JB/T8734.2-2016
300/500V Oxygen Free Copper Wire/PVC Insulated And The Core From 2~3 /Standard: IEC227-4 Or JB/T8734.2-2016
RVS Wire Rated Voltage Uo/U:300 / 300 V CU Conductor/ Electrical Wires And Cables Use for Builing and House
RVS Wire Rated Voltage Uo/U:300 / 300 V CU Conductor/ Electrical Wires And Cables Use for Builing and House
Low Smoking 2 Cores Cable , 300/300V RVB Cable For Home And Building /PVC Insulated
Low Smoking 2 Cores Cable , 300/300V RVB Cable For Home And Building /PVC Insulated
Building Class 5 Copper Conductor PVC Insulation RV / Flexible Cables
Building Class 5 Copper Conductor PVC Insulation RV / Flexible Cables
IEC 60227 Standard (CU/PVC/PVC) Twin And Earth Cable 2* 1.5mm, 2.5mm 4mm
IEC 60227 Standard (CU/PVC/PVC) Twin And Earth Cable 2* 1.5mm, 2.5mm 4mm
Send your message to this supplier
*From:
*To:

Zhenglan Cable Technology Co., Ltd

*Subject:
*Message:
Characters Remaining : (0/3000)
Contact Now